• Beranda
  • Cara Beli
  • Tentang Kami
  • Kontak Kami
  • Peta Situs
  • Konfirmasi Pembayaran
www.labkesprima.com
  • Peralatan Laboratorium  
    • Instruments  
      • Atomic Spectroscopy
      • Chromatography
      • Kjeldahl Digestion
      • Fibre Analysis
      • Spectrophotometer
      • Bomb Calorimeters
    • Equipment  
      • Biosafety Cabinets
      • Fumehoods and Enclosures
      • Ovens
      • Centrifuge
      • Furnaces
      • Incubators
      • Water Systems
      • Autoclave
      • Waterbath
      • Rotary Evaporators
    • Laboratory Apparatus  
      • Balances  
        • Analytical Balances
        • Electronic Toploading
        • Moisture Analyzers
      • PH Meter
      • Hotplate Stirrers
      • Shakers
      • Pumps
      • Microscoope  
        • Biological microscopes
        • Stereo Microscope
        • Inverted Microscope
    • Safety Product  
      • Koudx
    • Wildco
    • Glass Ware
    • General Instruments  
      • PETERNAKAN
  • Peralatan Kesehatan  
    • Surgical instruments
    • Stethoscopes & sphygmos
    • Scales and measures
    • First aid & emergency
    • Gynaecology
  • Peralatan Pendidikan Teknik  
    • Teknik Electro
    • Teknik Mesin
    • Teknik Sipil
    • Jurusan Kebidanan
    • Jurusan Gizi
    • Jurusan Keperawatan
    • Jurusan Listrik
  • Hamamatsu  
    • UV & flame sensors
    • Deuterium lamps
    • Hollow cathode lamp
    • Photodiodes
  • Digilent  
    • FPGA Development Boards & Kits
  • Novajets  
    • Turbine enggine
    • Turbine Jet Models
    • Electronics & Parts
  • Hobbyking  
    • Power Distribution  
      • VR/UBE/BEC/SBEC
    • Electric Motors
  • Mateksys  
    • Flight Controllers
    • Video Transmiters
    • DC Power & BEC Series
  • PowerBox Systems  
    • PowerBox Systems
  • Arduino  
    • BOARDS & MODULES
    • SHIELDS
    • KITS
  • Wildco  
    • Water Samplers  
      • Van Dorn Water Samplers  
        • Alpha Sampler Parts
        • Alpha Water Samplers, Horizontal
        • Alpha Water Samplers, Vertical
        • Beta Sampler Parts
        • Beta Water Samplers, Horizontal
        • Beta Water Samplers, Vertical
        • Series Sampling Beta Bottles
      • Kemmerer Water Samplers  
        • Fluoropolymer Kemmerer Water Sampler and Parts
        • Well Samplers and Well Sampler Parts
        • Non-Metallic Kemmerer Parts For 1500-1580 Series
        • Non-Metallic Kemmerer, General Purpose
        • Non-Metallic Kemmerer, Trace Metals
        • Stainless Steel Kemmerer Parts For 1200-1280 Series
        • Stainless Steel Kemmerer, Extreme Conditions
        • Stainless Steel Kemmerer, General Purpose
        • Stainless Steel Kemmerer, Trace Organics
    • Wastewater & Chemical Sampling  
      • Chemical Lab and Field Accessories
      • Chemical Test Kits
      • Student Test Kit
      • VOC Sampler
      • Wastewater Samplers
    • Stream Gaging Equipment  
      • Current Meters, Wading Rods, and Accessories
      • Depth-Integrating Samplers
    • Soil Sampling Equipment  
      • Sieves and Screens
      • Soil Tools
    • Plankton Equipment & Nets  
      • Plankton Equipment & Nets
      • Plankton Net Parts and Accessories  
        • Dolphin Adaptors
        • Dolphin Buckets
        • Guard rails for Dolphin Buckets
        • Nitex Bolting Cloth
        • Plankton Net Accessories
        • Ring and Bridle Assembly
        • Stainless Steel Mesh
      • Plankton Samplers and Processing
      • Wisconsin, Tow, and Birge Plankton Nets  
        • Birge Closing Nets
        • Tow Nets
        • Wisconsin Sampler
    • Lab Equipment & Accessories  
      • General Laboratory Equipment
      • Invertebrate Laboratory Equipment
      • Plankton Laboratory Equipment
    • Invertebrate Samplers & Nets  
      • Artificial Substrate Samplers
      • Flowing Water Samplers and Nets  
        • Drift Nets
        • Embededness Rings
        • Flowing Water Accessories
        • Hess Sampler
        • Surber Samplers  
          • 243um Surber Samplers
          • 363um Surber Samplers
          • 500um Surber Samplers
          • 600um Surber Samplers
          • 800um Surber Samplers
          • 1000um Surber Samplers
          • Surber Parts and Accessories
      • Invertebrate Collectors and Nets  
        • Invertebrate Collectors and Nets  
          • 243um D-Frame Dip Net
          • 243um Modified D-Frame Dip Net
          • 363um D-Frame Dip Net
          • 363um Modified D-Frame Dip Net
          • 425um D-Frame Dip Net
          • 500um D-Frame Dip Net
          • 500um Modified D-Frame Dip Net
          • 600um D-Frame Dip Net
          • 750um D-Frame Dip Net
          • 800\900um D-Frame Dip Net
          • 1000um D-Frame Dip Net
          • Replacement Parts for D-Frame Dip
        • Insect Nets
        • Invertebrate Counting Trays
        • Kick Nets  
          • Modified And Tapered Kick Nets
          • 243um Kick Net
          • 363um Kick Net
          • 425um Kick Net
          • 500um Kick Net
          • 600um Kick Net
          • 800\900um Kick Net
          • 1000um Kick Net
          • Replacement Parts For Kick Nets
        • Snag Nets
        • Tri-Nets
        • ZO Seine Nets
      • Zebra Mussel & Veliger Equipment
      • Zebra Mussel & Veliger Equipment
    • Groundwater Monitoring  
      • Heron Products
    • Fishery Equipment  
      • Field Fisheries Equipment
      • Fish Nets
      • Fisheries Laboratory Equipment
    • Fieldmaster® Student Sampling  
      • Fieldmaster® Student Kits
      • Student Field Equipment
      • Student Invertebrate Samplers
      • Student Laboratory Equipment
      • Student Plankton Samplers
      • Student Water Samplers
    • Field Equipment & Accessories  
      • Orienteering
      • Plastic Bottles and Dippers
    • Bottom Sampling Equipment  
      • Benthic Field Accessories
      • Benthic Grabs  
        • Van Veen Grab
        • Box Corer
        • Large Ekman Grab
        • Peterson Grab
        • Petite Ponar (small)
        • Shipek Grab
        • Standard Ekman Grab
        • Standard Ponar (large)
        • Tall Ekman Grab
      • Benthic Scoops and Sleds
      • Core Samplers  
        • Aquatic Suction Sampler
        • Ballcheck Corer
        • Core Sampler Accessories  
          • Core Sample Removal
          • Core Tubes, 2"
          • Corer Liner Tubes & Caps, 2"
          • Nose Pieces & Core Catchers
        • Flag Sampler \ Russian Peat Borer
        • Hand Corers
        • K-B Corers
        • Ogeechee Corer
    • Adult Insect Equipment  
      • Insect Field Equipment
      • Insect Kits
      • Insect Lab Equipment
    • School Supplies
    • Biology
    • Earth Science
    • Wine & Brew
    • Safety & Health
    • Glassware
    • Plasticware
    • Chemistry
    • Physics
    • CLEARANCE
    • Labware
  • SYSBEL Industry & Technology Co., Ltd.  
    • Safety Containment Systems  
      • Flammable Cabinets
  • Phoenix-Instrument  
    • Stirerr and Shaker
    • Centrifuge
    • Balance
    • Rotary Evaporator
    • Incubator
    • Oven
    • Waterbath
    • PH Meter
    • Vacuum Aspiration System VAS-10
    • MediJet500
  • Beranda
  • Cara Beli
  • Tentang Kami
  • Kontak Kami
  • Peta Situs
  • Konfirmasi Pembayaran
  • Hamamatsu

Information

Login

Shopping Cart

Categories

  • Peralatan Laboratorium
    • Instruments
      • Atomic Spectroscopy
      • Chromatography
      • Kjeldahl Digestion
      • Fibre Analysis
      • Spectrophotometer
      • Bomb Calorimeters
    • Equipment
      • Biosafety Cabinets
      • Fumehoods and Enclosures
      • Ovens
      • Centrifuge
      • Furnaces
      • Incubators
      • Water Systems
      • Autoclave
      • Waterbath
      • Rotary Evaporators
    • Laboratory Apparatus
      • Balances
        • Analytical Balances
        • Electronic Toploading
        • Moisture Analyzers
      • PH Meter
      • Hotplate Stirrers
      • Shakers
      • Pumps
      • Microscoope
        • Biological microscopes
        • Stereo Microscope
        • Inverted Microscope
    • Safety Product
      • Koudx
    • Wildco
    • Glass Ware
    • General Instruments
      • PETERNAKAN
  • Peralatan Kesehatan
    • Surgical instruments
    • Stethoscopes & sphygmos
    • Scales and measures
    • First aid & emergency
    • Gynaecology
  • Peralatan Pendidikan Teknik
    • Teknik Electro
    • Teknik Mesin
    • Teknik Sipil
    • Jurusan Kebidanan
    • Jurusan Gizi
    • Jurusan Keperawatan
    • Jurusan Listrik
  • Hamamatsu
    • UV & flame sensors
    • Deuterium lamps
    • Hollow cathode lamp
    • Photodiodes
  • Digilent
    • FPGA Development Boards & Kits
  • Novajets
    • Turbine enggine
    • Turbine Jet Models
    • Electronics & Parts
  • Hobbyking
    • Power Distribution
      • VR/UBE/BEC/SBEC
    • Electric Motors
  • Mateksys
    • Flight Controllers
    • Video Transmiters
    • DC Power & BEC Series
  • PowerBox Systems
    • PowerBox Systems
  • Arduino
    • BOARDS & MODULES
    • SHIELDS
    • KITS
  • Wildco
    • Water Samplers
      • Van Dorn Water Samplers
        • Alpha Sampler Parts
        • Alpha Water Samplers, Horizontal
        • Alpha Water Samplers, Vertical
        • Beta Sampler Parts
        • Beta Water Samplers, Horizontal
        • Beta Water Samplers, Vertical
        • Series Sampling Beta Bottles
      • Kemmerer Water Samplers
        • Fluoropolymer Kemmerer Water Sampler and Parts
        • Well Samplers and Well Sampler Parts
        • Non-Metallic Kemmerer Parts For 1500-1580 Series
        • Non-Metallic Kemmerer, General Purpose
        • Non-Metallic Kemmerer, Trace Metals
        • Stainless Steel Kemmerer Parts For 1200-1280 Series
        • Stainless Steel Kemmerer, Extreme Conditions
        • Stainless Steel Kemmerer, General Purpose
        • Stainless Steel Kemmerer, Trace Organics
    • Wastewater & Chemical Sampling
      • Chemical Lab and Field Accessories
      • Chemical Test Kits
      • Student Test Kit
      • VOC Sampler
      • Wastewater Samplers
    • Stream Gaging Equipment
      • Current Meters, Wading Rods, and Accessories
      • Depth-Integrating Samplers
    • Soil Sampling Equipment
      • Sieves and Screens
      • Soil Tools
    • Plankton Equipment & Nets
      • Plankton Equipment & Nets
      • Plankton Net Parts and Accessories
        • Dolphin Adaptors
        • Dolphin Buckets
        • Guard rails for Dolphin Buckets
        • Nitex Bolting Cloth
        • Plankton Net Accessories
        • Ring and Bridle Assembly
        • Stainless Steel Mesh
      • Plankton Samplers and Processing
      • Wisconsin, Tow, and Birge Plankton Nets
        • Birge Closing Nets
        • Tow Nets
        • Wisconsin Sampler
    • Lab Equipment & Accessories
      • General Laboratory Equipment
      • Invertebrate Laboratory Equipment
      • Plankton Laboratory Equipment
    • Invertebrate Samplers & Nets
      • Artificial Substrate Samplers
      • Flowing Water Samplers and Nets
        • Drift Nets
        • Embededness Rings
        • Flowing Water Accessories
        • Hess Sampler
        • Surber Samplers
          • 243um Surber Samplers
          • 363um Surber Samplers
          • 500um Surber Samplers
          • 600um Surber Samplers
          • 800um Surber Samplers
          • 1000um Surber Samplers
          • Surber Parts and Accessories
      • Invertebrate Collectors and Nets
        • Invertebrate Collectors and Nets
          • 243um D-Frame Dip Net
          • 243um Modified D-Frame Dip Net
          • 363um D-Frame Dip Net
          • 363um Modified D-Frame Dip Net
          • 425um D-Frame Dip Net
          • 500um D-Frame Dip Net
          • 500um Modified D-Frame Dip Net
          • 600um D-Frame Dip Net
          • 750um D-Frame Dip Net
          • 800\900um D-Frame Dip Net
          • 1000um D-Frame Dip Net
          • Replacement Parts for D-Frame Dip
        • Insect Nets
        • Invertebrate Counting Trays
        • Kick Nets
          • Modified And Tapered Kick Nets
          • 243um Kick Net
          • 363um Kick Net
          • 425um Kick Net
          • 500um Kick Net
          • 600um Kick Net
          • 800\900um Kick Net
          • 1000um Kick Net
          • Replacement Parts For Kick Nets
        • Snag Nets
        • Tri-Nets
        • ZO Seine Nets
      • Zebra Mussel & Veliger Equipment
      • Zebra Mussel & Veliger Equipment
    • Groundwater Monitoring
      • Heron Products
    • Fishery Equipment
      • Field Fisheries Equipment
      • Fish Nets
      • Fisheries Laboratory Equipment
    • Fieldmaster® Student Sampling
      • Fieldmaster® Student Kits
      • Student Field Equipment
      • Student Invertebrate Samplers
      • Student Laboratory Equipment
      • Student Plankton Samplers
      • Student Water Samplers
    • Field Equipment & Accessories
      • Orienteering
      • Plastic Bottles and Dippers
    • Bottom Sampling Equipment
      • Benthic Field Accessories
      • Benthic Grabs
        • Van Veen Grab
        • Box Corer
        • Large Ekman Grab
        • Peterson Grab
        • Petite Ponar (small)
        • Shipek Grab
        • Standard Ekman Grab
        • Standard Ponar (large)
        • Tall Ekman Grab
      • Benthic Scoops and Sleds
      • Core Samplers
        • Aquatic Suction Sampler
        • Ballcheck Corer
        • Core Sampler Accessories
          • Core Sample Removal
          • Core Tubes, 2"
          • Corer Liner Tubes & Caps, 2"
          • Nose Pieces & Core Catchers
        • Flag Sampler \ Russian Peat Borer
        • Hand Corers
        • K-B Corers
        • Ogeechee Corer
    • Adult Insect Equipment
      • Insect Field Equipment
      • Insect Kits
      • Insect Lab Equipment
    • School Supplies
    • Biology
    • Earth Science
    • Wine & Brew
    • Safety & Health
    • Glassware
    • Plasticware
    • Chemistry
    • Physics
    • CLEARANCE
    • Labware
  • SYSBEL Industry & Technology Co., Ltd.
    • Safety Containment Systems
      • Flammable Cabinets
  • Phoenix-Instrument
    • Stirerr and Shaker
    • Centrifuge
    • Balance
    • Rotary Evaporator
    • Incubator
    • Oven
    • Waterbath
    • PH Meter
    • Vacuum Aspiration System VAS-10
    • MediJet500

Filter by Price

  • ≤ Rp 200.000
  • Rp 200.001 - Rp 600.000
  • Rp 600.001 - Rp 1.000.000
  • ≥ Rp 1.000.001

Testimonial

» lihat testimonial
» isi testimonial

USD Calculator

x Rp. 14,400
berhasil ditambahkan ke keranjang.

Hamamatsu

Refine Search

UV & flame sensors
Deuterium lamps
Hollow cathode lamp
Photodiodes
Display :
  • «
  • 1
  • 2
  • »
Sort By:
  Deuterium lamp (L2D2 lamp) L12307

Deuterium lamp (L2D2 lamp) L12307

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 12 to 15 V dc, V ac
Filament Warm-up Current Typ. 0.5 to 0.55 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 0 (*1) V dc
Filament Operating Current Typ. 0 (*1) A dc
Notes (*1) During lamp operation a discharge current flows into the filament so no external power supply is needed to maintain the filament temperature.
  Deuterium lamp (L2D2 lamp) L12313

Deuterium lamp (L2D2 lamp) L12313

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 3.0 V dc, V ac
Filament Warm-up Current Typ. 5 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 0 to 1 V dc
Filament Operating Current Typ. 0 to 1.8 A dc
  Deuterium lamp (L2D2 lamp) L12313-50

Deuterium lamp (L2D2 lamp) L12313-50

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 3.0 V dc, V ac
Filament Warm-up Current Typ. 5 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 0 to 1 V dc
Filament Operating Current Typ. 0 to 1.8 A dc

 

  Deuterium lamp (L2D2 lamp) L6301

Deuterium lamp (L2D2 lamp) L6301

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
  Deuterium lamp (L2D2 lamp) L6301-50

Deuterium lamp (L2D2 lamp) L6301-50

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
  Deuterium lamp (L2D2 lamp) L6303

Deuterium lamp (L2D2 lamp) L6303

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.7 +/- 0.2 V dc
Filament Operating Current Typ. 3.3 A dc
  Deuterium lamp (L2D2 lamp) L6307

Deuterium lamp (L2D2 lamp) L6307

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 10 +/- 1 V dc, V ac
Filament Warm-up Current Typ. 0.8 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 2.5 to 6.0 V dc
Filament Operating Current Typ. 0.3 to 0.6 A dc
  Deuterium lamp (L2D2 lamp) L6309

Deuterium lamp (L2D2 lamp) L6309

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 10 +/- 1 V dc, V ac
Filament Warm-up Current Typ. 1.2 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 7.0 +/- 0.5 V dc
Filament Operating Current Typ. 1 A dc
  Deuterium lamp (L2D2 lamp) L7296

Deuterium lamp (L2D2 lamp) L7296

Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material Synthetic Silica
Spectral Distribution (Short) 160 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 10 +/- 1 V dc, V ac
Filament Warm-up Current Typ. 1.2 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 7.0 +/- 0.5 V dc
Filament Operating Current Typ. 1 A dc
  Deuterium lamp (L2D2 lamp) L7296-50

Deuterium lamp (L2D2 lamp) L7296-50

Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure Standard
Window Material Synthetic Silica
Spectral Distribution (Short) 160 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 10 +/- 1 V dc, V ac
Filament Warm-up Current Typ. 1.2 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 7.0 +/- 0.5 V dc
Filament Operating Current Typ. 1 A dc
  Deuterium lamp (L2D2 lamp) L9030

Deuterium lamp (L2D2 lamp) L9030

Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure See-through
Window Material Synthetic Silica
Spectral Distribution (Short) 160 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
  Deuterium lamp (L2d2 lamp) L9030-50

Deuterium lamp (L2d2 lamp) L9030-50

Spectral distribution : 160 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series L2-2000
Electrode Structure See-through
Window Material Synthetic Silica
Spectral Distribution (Short) 160 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
  Deuterium lamp (X2D2 lamp) L10804

Deuterium lamp (X2D2 lamp) L10804

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series X2D2
Electrode Structure See-through
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 90.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.7 +/- 0.2 V dc
Filament Operating Current Typ. 3.3 A dc
  Deuterium lamp (X2D2 lamp) L10904

Deuterium lamp (X2D2 lamp) L10904

Spectral distribution : 160 to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series X2D2
Electrode Structure See-through
Window Material Synthetic Silica
Spectral Distribution (Short) 160 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 85.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.7 +/- 0.2 V dc
Filament Operating Current Typ. 3.3 A dc
  Deuterium lamp (X2D2 lamp) L9518

Deuterium lamp (X2D2 lamp) L9518

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series X2D2
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 90.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.7 +/- 0.2 V dc
Filament Operating Current Typ. 3.3 A dc
  Deuterium lamp (X2D2 lamp) L9519

Deuterium lamp (X2D2 lamp) L9519

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series X2D2
Electrode Structure Standard
Window Material Synthetic Silica
Spectral Distribution (Short) 160 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 85.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.7 +/- 0.2 V dc
Filament Operating Current Typ. 3.3 A dc
  Deuterium lamp (X2D2 lamp) L9841

Deuterium lamp (X2D2 lamp) L9841

Spectral distribution : 115 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications

Series X2D2
Electrode Structure Standard
Window Material MgF2
Spectral Distribution (Short) 115 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 85.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.7 +/- 0.2 V dc
Filament Operating Current Typ. 3.3 A dc
  Si photodiode S12497

Si photodiode S12497

A scintillator can be mounted directly on the chip.

The S12497 is a Si photodiode suitable for non-destructive inspection of baggage and the like and general industrial measurement. As it is a back-illuminated photodiode, photosensitive area does not have wires, and therefore a scintillator can be mounted directly on the photodiode.


Features
- Spectral response range : 400 to 1100 nm
- Photosensitive area: 9.5 × 9.5 mm - Easy scintillator mounting

Notice

The chip of this product is not sealed and is exposed. Parts such as electrodes on the chip are not protected by an enclosure or window and so require especially strict care during handling compared to ordinary products.
Before using this product, always read “Unsealed products / Precautions” described below.

Specifications

Photosensitive area 9.5 × 9.5 mm
Number of elements 1
Package PWB with pins
Cooling Non-cooled
Reverse voltage (max.) 10 V
Spectral response range 400 to 1100 nm
Peak sensitivity wavelength (typ.) 920 nm
Photosensitivity (typ.) 0.57 A/W
Dark current (max.) 200 pA
Rise time (typ.) 15 μs
Terminal capacitance (typ.) 950 pF
Measurement condition Typ. Ta=25 ℃, unless otherwise noted,
Photosensitivity: λ=920 nm, Dark current: VR=10 mV, Terminal capacitance: VR=0 V, f=10 kHz
  Si photodiode S12498

Si photodiode S12498

A scintillator can be mounted directly on the chip.

The S12498 is a Si photodiode suitable for non-destructive inspection of baggage and the like and general industrial measurement. As it is a back-illuminated photodiode, photosensitive area does not have wires, and therefore a scintillator can be mounted directly on the photodiode.


Features
- Spectral response range : 400 to 1100 nm
- Photosensitive area: 6.0 × 6.0 mm - Easy scintillator mounting

Notice

The chip of this product is not sealed and is exposed. Parts such as electrodes on the chip are not protected by an enclosure or window and so require especially strict care during handling compared to ordinary products.
Before using this product, always read “Unsealed products / Precautions” described below.

Specifications

Photosensitive area 6.0 × 6.0 mm
Number of elements 1
Package PWB with pins
Cooling Non-cooled
Reverse voltage (max.) 10 V
Spectral response range 400 to 1100 nm
Peak sensitivity wavelength (typ.) 920 nm
Photosensitivity (typ.) 0.57 A/W
Dark current (max.) 150 pA
Rise time (typ.) 15 μs
Terminal capacitance (typ.) 380 pF
Measurement condition Typ. Ta=25 ℃, unless otherwise noted,
Photosensitivity: λ=920 nm, Dark current: VR=10 mV, Terminal capacitance: VR=0 V, f=10 kHz

  Si photodiode S12915-1010R

Si photodiode S12915-1010R

For visible to IR, general-purpose photometry

S12915 series have high sensitivity in the visible range to near IR.
They provide higher sensitivity than the S2387 series and can be used in high-humidity environments.


Features
- High sensitivity in visible to infrared range
- Low dark current
- High linearity

Specifications

Constitution NEW Conventional product Unit
Type no. S12915-1010R S2387-1010R -
Window material Plastic potting -
Package 15 × 16.5 mm
Photosensitive area size 10 × 10 mm
Effective photosensitive area 100 mm2
Reverse voltage Max. 30 V
Operating temperature -20 ~ +60 ℃
Storage temperature -20 ~ +80 ℃
Spectral response range 340 ~ 1100 nm
Peak sensitivity wavelength 960 nm
Photosensitivity Typ. 0.64 0.58 A/W
Short circuit current Typ. 95 91 μA
Dark current Max. 200 pA
Temp. coefficient of ID 1.12 times/℃
Rise time Typ. 33 μs
Terminal capacitance Typ. 13000 12000 pF
Shunt resistance Typ. 5 GΩ
Noise equivalent power 2.8 × 10-15 3.1 × 10-15 W/Hz1/2
Measurement conditions Typ. Ta=25 °C, unless otherwise noted, Dark current: VR=10 mV, Rise time: VR=0 V,
Shunt resistance: R=10 mV, Noise equivalent power: VR=0 V
Deuterium lamp (L2D2 lamp)  L6565

Deuterium lamp (L2D2 lamp) L6565

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications
Series
L2-4000
Electrode Structure Standard
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 1 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 4000 h
Required Discharge Starting Voltage Min. 350.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
Deuterium lamp (L2D2 lamp)  L6999

Deuterium lamp (L2D2 lamp) L6999

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications
Series
L2-2000
Electrode Structure See-through
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
Deuterium lamp (L2D2 lamp)  L6999-50

Deuterium lamp (L2D2 lamp) L6999-50

Spectral distribution : 185 nm to 400 nm, Aperture diameter : 0.5 mm, Guaranteed life : 2000 h

Specifications
Series
L2-2000
Electrode Structure See-through
Window Material UV Glass
Spectral Distribution (Short) 185 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 0.5 mm
Output Stability Drift Max. +/- 0.3 %/h
Output Stability Fluctuation (p-p) Typ. 0.005 %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 400.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
Deuterium lamp (L2D2 lamp)  L7293

Deuterium lamp (L2D2 lamp) L7293

Spectral distribution : 115 nm to 400 nm, Aperture diameter : 1.0 mm, Guaranteed life : 2000 h

Specifications
Series
L2-2000
Electrode Structure Standard
Window Material MgF2
Spectral Distribution (Short) 115 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 1 mm
Output Stability Drift Max. - %/h
Output Stability Fluctuation (p-p) Typ. - %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 350.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
Deuterium lamp (L2D2 lamp)  L7293-50

Deuterium lamp (L2D2 lamp) L7293-50

Spectral distribution : 115 nm to 400 nm, Aperture diameter : 1.0 mm, Guaranteed life : 2000 h

Specifications
Series
L2-2000
Electrode Structure Standard
Window Material MgF2
Spectral Distribution (Short) 115 nm
Spectral Distribution (Long) 400 nm
Aperture Diameter *a 1 mm
Output Stability Drift Max. - %/h
Output Stability Fluctuation (p-p) Typ. - %
Guaranteed Life *d 2000 h
Required Discharge Starting Voltage Min. 350.0 V dc
Anode Current 300 +/- 30 mA dc
Tube Drop Voltage Typ. 80.0 V dc
Filament Warm-up Voltage 2.5 +/- 0.25 V dc, V ac
Filament Warm-up Current Typ. 4 A dc, A ac
Filament Warm-up Time 20 s
Filament Operating Voltage 1.0 +/- 0.1 V dc
Filament Operating Current Typ. 1.8 A dc
Flame sensor (UV TRON)  R12257

Flame sensor (UV TRON) R12257

The UVTRON ultraviolet ON/OFF detector that makes use of the photoelectric effect of metal and the gas multiplication effect. It has a narrow spectral sensitivity of 185 nm to 300 nm, being completely insensitive to visible light. Unlike semiconductor detectors, it dose not require optical visible-cut filters, thus making it easy to use.

Specifications
Spectral Response (Short)
185 nm
Spectral Response (Long) 300 nm
Electrode Material Mo
Weight 5 g
[Maximum Rating] Supply Voltage (DC) 425 V
[Maximum Rating] Average Discharge Current 10 mA
[Maximum Rating] Peak Current 200 mA
[Maximum Rating] Operation Ambient Temperature -20 to +125 â„ƒ
Discharge Starting Voltage (DC) 240 V
Discharge Sustaining Voltage (DC) 170 V
Sensitivitiy Typ. 1200 min-1
Background Max. 10 min-1
Average Life 10000 h
[Recommended Operating Parameters] Supply Voltage (DC) 310±25 V
[Recommended Operating Parameters] Average Discharge Current 2 mA
[Recommended Operating Parameters] Quenching Time Min. 1 ms
Suitable Socket (Sold Separately) E678-9C
Flame sensor (UV TRON)  R13192

Flame sensor (UV TRON) R13192

The R13192 delivers enhanced sensitivity through a new design of the photosensitive area.

Features

Detects fire from long distances (high sensitivity)
Detects only UV light without using any optical filtersApplications
Fire detection in a building with large space
Arson surveillance
Discharge detection
Specifications
Spectral Response (Short)
185 nm
Spectral Response (Long) 260 nm
Electrode Material Ni
Weight 5.2 g
[Maximum Rating] Supply Voltage (DC) 420 V
[Maximum Rating] Average Discharge Current 3 mA
[Maximum Rating] Peak Current 50 mA
[Maximum Rating] Operation Ambient Temperature -20 to +125 â„ƒ
Discharge Starting Voltage (DC) 260 V
Discharge Sustaining Voltage (DC) 185 V
Sensitivitiy Typ. 15000 min-1
Background Max. 5 min-1
Average Life 25000 h
[Recommended Operating Parameters] Supply Voltage (DC) 325±25 V
[Recommended Operating Parameters] Average Discharge Current 0.3 mA
[Recommended Operating Parameters] Quenching Time Min. 2 ms
Suitable Socket (Sold Separately) E678-9C
Flame sensor (UV TRON)  R244

Flame sensor (UV TRON) R244

The UVTRON ultraviolet ON/OFF detector that makes use of the photoelectric effect of metal and the gas multiplication effect. It has a narrow spectral sensitivity of 185 nm to 260 nm, being completely insensitive to visible light. Unlike semiconductor detectors, it dose not require optical visible-cut filters, thus making it easy to use.

Specifications
Spectral Response (Short)
185 nm
Spectral Response (Long) 260 nm
Electrode Material Ni
Weight 3 g
[Maximum Rating] Supply Voltage (DC) 575 V
[Maximum Rating] Average Discharge Current 3 mA
[Maximum Rating] Peak Current 50 mA
[Maximum Rating] Operation Ambient Temperature -20 to +125 â„ƒ
Discharge Starting Voltage (DC) 440 V
Discharge Sustaining Voltage (DC) 330 V
Sensitivitiy Typ. 480 min-1
Background Max. 5 min-1
Average Life 10000 h
[Recommended Operating Parameters] Supply Voltage (DC) 500±50 V
[Recommended Operating Parameters] Average Discharge Current 0.3 mA
[Recommended Operating Parameters] Quenching Time Min. 3 ms
Flame sensor (UV TRON)  R2868

Flame sensor (UV TRON) R2868

R2868 is a UVTRON ultraviolet ON/OFF detector that makes use of the photoelectric effect of metal and the gas multiplication effect. It has a narrow spectral sensitivity of 185 nm to 260 nm, being completely insensitive to visible light. Unlike semiconductor detectors, it dose not require optical visible-cut filters, thus making it easy to use

Specifications
Spectral Response (Short)
185 nm
Spectral Response (Long) 260 nm
Electrode Material Ni
Weight 1.5 g
[Maximum Rating] Supply Voltage (DC) 400 V
[Maximum Rating] Average Discharge Current 1 mA
[Maximum Rating] Peak Current 30 mA
[Maximum Rating] Operation Ambient Temperature -20 to +60 â„ƒ
Discharge Starting Voltage (DC) 280 V
Discharge Sustaining Voltage (DC) 240 V
Sensitivitiy Typ. 5000 min-1
Background Max. 10 min-1
Average Life 10000 h
[Recommended Operating Parameters] Supply Voltage (DC) 325±25 V
[Recommended Operating Parameters] Average Discharge Current 0.3 mA
[Recommended Operating Parameters] Quenching Time Min. 2 ms
Rp 2.100.000
Beli
Flame sensor (UV TRON)  R9454

Flame sensor (UV TRON) R9454

The R9454 is the side-on type (UV light enters from the bulb side) having a similar shape to the R2868 UVtron and also offers high sensitivity and a wide field of view (directivity).

Specifications
Spectral Response (Short)
185 nm
Spectral Response (Long) 260 nm
Electrode Material Ni
Weight 1.5 g
[Maximum Rating] Supply Voltage (DC) 500 V
[Maximum Rating] Average Discharge Current 1 mA
[Maximum Rating] Peak Current 30 mA
[Maximum Rating] Operation Ambient Temperature -20 to +60 â„ƒ
Discharge Starting Voltage (DC) 360 V
Discharge Sustaining Voltage (DC) 300 V
Sensitivitiy Typ. 4000 min-1
Background Max. 10 min-1
Average Life 10000 h
[Recommended Operating Parameters] Supply Voltage (DC) 400±25 V
[Recommended Operating Parameters] Average Discharge Current 0.3 mA
[Recommended Operating Parameters] Quenching Time Min. 2 ms

Flame sensor (UV TRON) R9533

Flame sensor (UV TRON) R9533

The R9533 is a head-on type (UV light enters from the bulb top) that easily installs in most equipment and has high sensitivity and a wide field of view.

Specifications  
Spectral Response (Short)
185 nm
Spectral Response (Long) 260 nm
Electrode Material Ni
Weight 2.5 g
[Maximum Rating] Supply Voltage (DC) 400 V
[Maximum Rating] Average Discharge Current 1 mA
[Maximum Rating] Peak Current 30 mA
[Maximum Rating] Operation Ambient Temperature -20 to +125 â„ƒ
Discharge Starting Voltage (DC) 280 V
Discharge Sustaining Voltage (DC) 230 V
Sensitivitiy Typ. 10000 min-1
Background Max. 10 min-1
Average Life 10000 h
[Recommended Operating Parameters] Supply Voltage (DC) 350±25 V
[Recommended Operating Parameters] Average Discharge Current 0.3 mA
[Recommended Operating Parameters] Quenching Time Min. 1 ms
Suitable Socket (Sold Separately) E678-8F

Hollow cathode lamp  L233-11NB

Hollow cathode lamp L233-11NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Sodium

Specifications

Lamp Diameter 38
Element symbol Na
Element Name Sodium
Analysis Lines (Maximum absorption wavelength) 589 nm
Analysis Lines 589.59 nm
Hollow cathode lamp  L233-12NU

Hollow cathode lamp L233-12NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Magnesium

Specifications
Lamp Diameter
38
Element symbol Mg
Element Name Magnesium
Analysis Lines (Maximum absorption wavelength) 285.21 nm
Analysis Lines - nm
Hollow cathode lamp  L233-13NB

Hollow cathode lamp L233-13NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Aluminum

Specifications
Lamp Diameter
38
Element symbol Al
Element Name Aluminum
Analysis Lines (Maximum absorption wavelength) 309.27 nm
Analysis Lines 396.15 nm
Hollow cathode lamp  L233-14NU

Hollow cathode lamp L233-14NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Silicon

Specifications
Lamp Diameter
38
Element symbol Si
Element Name Silicon
Analysis Lines (Maximum absorption wavelength) 251.61 nm
Analysis Lines 288.16 nm
Hollow cathode lamp  L233-19NB

Hollow cathode lamp L233-19NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Potassium

Specifications

Lamp Diameter 38
Element symbol K
Element Name Potassium
Analysis Lines (Maximum absorption wavelength) 766.49 nm
Analysis Lines 769.9 nm
Hollow cathode lamp  L233-19NB

Hollow cathode lamp L233-19NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Deuterium

Specifications
Lamp Diameter
38
Element symbol D2
Element Name Deuterium
Analysis Lines (Maximum absorption wavelength) - nm
Analysis Lines 240 nm
Hollow cathode lamp  L233-20NU

Hollow cathode lamp L233-20NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Calcium

Specifications
Lamp Diameter
38
Element symbol Ca
Element Name Calcium
Analysis Lines (Maximum absorption wavelength) 422.67 nm
Analysis Lines - nm
Hollow cathode lamp  L233-21NB

Hollow cathode lamp L233-21NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Scandium

Specifications
Lamp Diameter
38
Element symbol Sc
Element Name Scandium
Analysis Lines (Maximum absorption wavelength) 391.18 nm
Analysis Lines 390.74 nm
Hollow cathode lamp  L233-22NB

Hollow cathode lamp L233-22NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Titanium

Specifications
Lamp Diameter
38
Element symbol Ti
Element Name Titanium
Analysis Lines (Maximum absorption wavelength) 364.27 nm
Analysis Lines 365.35 nm
Hollow cathode lamp  L233-23NB

Hollow cathode lamp L233-23NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Vanadium

Specifications
Lamp Diameter
38
Element symbol V
Element Name Vanadium
Analysis Lines (Maximum absorption wavelength) 318.4 nm
Analysis Lines 306.64 nm
Hollow cathode lamp  L233-24NB

Hollow cathode lamp L233-24NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Chromium

Specifications
Lamp Diameter
38
Element symbol Cr
Element Name Chromium
Analysis Lines (Maximum absorption wavelength) 357.87 nm
Analysis Lines 425.44 nm
Hollow cathode lamp  L233-25NU

Hollow cathode lamp L233-25NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Manganese

Specifications
Lamp Diameter
38
Element symbol Mn
Element Name Manganese
Analysis Lines (Maximum absorption wavelength) 279.48 nm
Analysis Lines 403.08 nm
Hollow cathode lamp  L233-26NU

Hollow cathode lamp L233-26NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Iron

Specifications
Lamp Diameter
38
Element symbol Fe
Element Name Iron
Analysis Lines (Maximum absorption wavelength) 248.33 nm
Analysis Lines 371.99 nm
Hollow cathode lamp  L233-27NU

Hollow cathode lamp L233-27NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Cobalt

Specifications
Lamp Diameter
38
Element symbol Co
Element Name Cobalt
Analysis Lines (Maximum absorption wavelength) 240.73 nm
Analysis Lines 346.58 nm
Hollow cathode lamp  L233-28NQ

Hollow cathode lamp L233-28NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Nickel

Specifications
Lamp Diameter
38
Element symbol Ni
Element Name Nickel
Analysis Lines (Maximum absorption wavelength) 232 nm
Analysis Lines 341.48 nm
Hollow cathode lamp  L233-29NB

Hollow cathode lamp L233-29NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Copper

Specifications
Lamp Diameter
38
Element symbol Cu
Element Name Copper
Analysis Lines (Maximum absorption wavelength) 324.75 nm
Analysis Lines 327.4 nm
Hollow cathode lamp  L233-30NQ

Hollow cathode lamp L233-30NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Zinc

Specifications
Lamp Diameter
38
Element symbol Zn
Element Name Zinc
Analysis Lines (Maximum absorption wavelength) 213.86 nm
Analysis Lines 307.59 nm
Hollow cathode lamp  L233-31NU

Hollow cathode lamp L233-31NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Gallium

Specifications
Lamp Diameter
38
Element symbol Ga
Element Name Gallium
Analysis Lines (Maximum absorption wavelength) 294.36 nm
Analysis Lines 287.42 nm
Hollow cathode lamp  L233-32NU

Hollow cathode lamp L233-32NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Germanium

Specifications
Lamp Diameter
38
Element symbol Ge
Element Name Germanium
Analysis Lines (Maximum absorption wavelength) 265.16 nm
Analysis Lines - nm
Hollow cathode lamp  L233-33NQ

Hollow cathode lamp L233-33NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Arsenic

Specifications
Lamp Diameter
38
Element symbol As
Element Name Arsenic
Analysis Lines (Maximum absorption wavelength) 193.7 nm
Analysis Lines 197.2 nm
Hollow cathode lamp  L233-34NQ

Hollow cathode lamp L233-34NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Selenium

Specifications
Lamp Diameter
38
Element symbol Se
Element Name Selenium
Analysis Lines (Maximum absorption wavelength) 196.03 nm
Analysis Lines - nm
Hollow cathode lamp  L233-37NB

Hollow cathode lamp L233-37NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Rubidium

Specifications  
Lamp Diameter
38
Element symbol Rb
Element Name Rubidium
Analysis Lines (Maximum absorption wavelength) 780.02 nm
Analysis Lines 794.76 nm
Hollow cathode lamp  L233-38NB

Hollow cathode lamp L233-38NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Strontium

Specifications  
Lamp Diameter
38
Element symbol Sr
Element Name Strontium
Analysis Lines (Maximum absorption wavelength) 460.73 nm
Analysis Lines - nm
Hollow cathode lamp  L233-39NB

Hollow cathode lamp L233-39NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Yttrium

Specifications  
Lamp Diameter
38
Element symbol Y
Element Name Yttrium
Analysis Lines (Maximum absorption wavelength) 410.23 nm
Analysis Lines 412.83 nm
Hollow cathode lamp  L233-3NB

Hollow cathode lamp L233-3NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Lithium

Specifications  
Lamp Diameter
38
Element symbol Li
Element Name Lithium
Analysis Lines (Maximum absorption wavelength) 670.78 nm
Analysis Lines 610.36 nm
Hollow cathode lamp  L233-40NB

Hollow cathode lamp L233-40NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Zirconium

Specifications  
Lamp Diameter
38
Element symbol Zr
Element Name Zirconium
Analysis Lines (Maximum absorption wavelength) 360.12 nm
Analysis Lines 468.78 nm
Hollow cathode lamp  L233-41NB

Hollow cathode lamp L233-41NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Niobium

Specifications  
Lamp Diameter
38
Element symbol Nb
Element Name Niobium
Analysis Lines (Maximum absorption wavelength) 334.91 nm
Analysis Lines 405.89 nm
Hollow cathode lamp  L233-42NB

Hollow cathode lamp L233-42NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Molybdenum

Specifications  
Lamp Diameter
38
Element symbol Mo
Element Name Molybdenum
Analysis Lines (Maximum absorption wavelength) 313.26 nm
Analysis Lines 320.88 nm
Hollow cathode lamp  L233-44NB

Hollow cathode lamp L233-44NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Ruthenium

Specifications  
Lamp Diameter
38
Element symbol Ru
Element Name Ruthenium
Analysis Lines (Maximum absorption wavelength) 348.89 nm
Analysis Lines - nm
Hollow cathode lamp  L233-45NB

Hollow cathode lamp L233-45NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Rhodium

Specifications  
Lamp Diameter
38
Element symbol Rh
Element Name Rhodium
Analysis Lines (Maximum absorption wavelength) 343.49 nm
Analysis Lines - nm
Hollow cathode lamp  L233-46NQ

Hollow cathode lamp L233-46NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Palladium

Specifications  
Lamp Diameter
38
Element symbol Pd
Element Name Palladium
Analysis Lines (Maximum absorption wavelength) 244.79 nm
Analysis Lines 247.64 nm
Hollow cathode lamp  L233-47NB

Hollow cathode lamp L233-47NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Silver

Specifications  
Lamp Diameter
38
Element symbol Ag
Element Name Silver
Analysis Lines (Maximum absorption wavelength) 328.07 nm
Analysis Lines 338.28 nm
Hollow cathode lamp  L233-48NQ

Hollow cathode lamp L233-48NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Cadmium

Specifications  
Lamp Diameter
38
Element symbol Cd
Element Name Cadmium
Analysis Lines (Maximum absorption wavelength) 228.8 nm
Analysis Lines - nm
Hollow cathode lamp  L233-49NB

Hollow cathode lamp L233-49NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Indium

Specifications  
Lamp Diameter
38
Element symbol In
Element Name Indium
Analysis Lines (Maximum absorption wavelength) 303.94 nm
Analysis Lines 325.61 nm
Hollow cathode lamp  L233-4NQ

Hollow cathode lamp L233-4NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Beryllium

Specifications  
Lamp Diameter
38
Element symbol Be
Element Name Beryllium
Analysis Lines (Maximum absorption wavelength) 234.86 nm
Analysis Lines - nm
Hollow cathode lamp  L233-50NQ

Hollow cathode lamp L233-50NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Tin

Specifications  
Lamp Diameter
38
Element symbol Sn
Element Name Tin
Analysis Lines (Maximum absorption wavelength) 224.61 nm
Analysis Lines 286.33 nm
Hollow cathode lamp  L233-51NQ

Hollow cathode lamp L233-51NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Antimony

Specifications  
Lamp Diameter
38
Element symbol Sb
Element Name Antimony
Analysis Lines (Maximum absorption wavelength) 217.58 nm
Analysis Lines 231.15 nm
Hollow cathode lamp  L233-52NQ

Hollow cathode lamp L233-52NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Tellurium

Specifications  
Lamp Diameter
38
Element symbol Te
Element Name Tellurium
Analysis Lines (Maximum absorption wavelength) 214.27 nm
Analysis Lines - nm
Hollow cathode lamp  L233-55NB

Hollow cathode lamp L233-55NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Cesium

Specifications  
Lamp Diameter
38
Element symbol Cs
Element Name Cesium
Analysis Lines (Maximum absorption wavelength) 852.11 nm
Analysis Lines  - nm
Hollow cathode lamp  L233-56NB

Hollow cathode lamp L233-56NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Barium

Specifications  
Lamp Diameter
38
Element symbol Ba
Element Name Barium
Analysis Lines (Maximum absorption wavelength) 553.55 nm
Analysis Lines - nm
Hollow cathode lamp  L233-57NB

Hollow cathode lamp L233-57NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Lanthanum

Specifications
Lamp Diameter
38
Element symbol La
Element Name Lanthanum
Analysis Lines (Maximum absorption wavelength) 550.13 nm
Analysis Lines 357.44 nm
Hollow cathode lamp  L2433-66NB

Hollow cathode lamp L2433-66NB

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Dysprosium

Specifications  
Lamp Diameter
38
Element symbol Dy
Element Name Dysprosium
Analysis Lines (Maximum absorption wavelength) 404.59 nm
Analysis Lines 421.17 nm
Hollow cathode lamp  Praseodymium L233-59NB

Hollow cathode lamp Praseodymium L233-59NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Praseodymium

Specifications  
Lamp Diameter
38
Element symbol Pr
Element Name Praseodymium
Analysis Lines (Maximum absorption wavelength) 495.13 nm
Analysis Lines 513.34 nm
Hollow cathode lamp  Strontium Barium L733-205NB

Hollow cathode lamp Strontium Barium L733-205NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Strontium Barium

Specifications  
Lamp Diameter
38
Element symbol Sr-Ba
Element Name Strontium Barium
Analysis Lines (Maximum absorption wavelength) - nm
Analysis Lines - nm
Hollow cathode lamp Aluminum Calcium Magnesium  L733-321NU

Hollow cathode lamp Aluminum Calcium Magnesium L733-321NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Aluminum Calcium Magnesium

Specifications
 
Lamp Diameter
38
Element symbol Al-Ca-Mg
Element Name Aluminum Calcium Magnesium
Analysis Lines (Maximum absorption wavelength) - nm
Analysis Lines - nm
Hollow cathode lamp Aluminum L2433-13NB

Hollow cathode lamp Aluminum L2433-13NB

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Aluminum

Specifications  
Lamp Diameter
38
Element symbol Al
Element Name Aluminum
Analysis Lines (Maximum absorption wavelength) 309.27 nm
Analysis Lines 396.15 nm
Hollow cathode lamp Antimony L2433-51NQ

Hollow cathode lamp Antimony L2433-51NQ

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Antimony

Specifications  
Lamp Diameter
38
Element symbol Sb
Element Name Antimony
Analysis Lines (Maximum absorption wavelength) 217.58 nm
Analysis Lines 231.15 nm
Hollow cathode lamp Arsenic L2433-33NQ

Hollow cathode lamp Arsenic L2433-33NQ

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Arsenic

Specifications  
Lamp Diameter
38
Element symbol As
Element Name Arsenic
Analysis Lines (Maximum absorption wavelength) 193.7 nm
Analysis Lines 197.2 nm
Hollow cathode lamp Barium L2433-56NB

Hollow cathode lamp Barium L2433-56NB

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Barium

Specifications  
Lamp Diameter
38
Element symbol Ba
Element Name Barium
Analysis Lines (Maximum absorption wavelength) 553.55 nm
Analysis Lines - nm
Hollow cathode lamp Beryllium L2433-4NQ

Hollow cathode lamp Beryllium L2433-4NQ

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Beryllium

Specifications  
Lamp Diameter
38
Element symbol Be
Element Name Beryllium
Analysis Lines (Maximum absorption wavelength) 234.86 nm
Analysis Lines - nm
Hollow cathode lamp Bismuth L233-83NQ

Hollow cathode lamp Bismuth L233-83NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Bismuth

Specifications  
Lamp Diameter
38
Element symbol Bi
Element Name Bismuth
Analysis Lines (Maximum absorption wavelength) 223.06 nm
Analysis Lines 306.77 nm
Hollow cathode lamp Bismuth L2433-83NQ

Hollow cathode lamp Bismuth L2433-83NQ

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Bismuth

Specifications
 
Lamp Diameter
38
Element symbol Bi
Element Name Bismuth
Analysis Lines (Maximum absorption wavelength) 223.06 nm
Analysis Lines 306.77 nm
Hollow cathode lamp Boron  L233-5NQ

Hollow cathode lamp Boron L233-5NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Boron

Specifications  
Lamp Diameter
38
Element symbol B
Element Name Boron
Analysis Lines (Maximum absorption wavelength) 249.68 nm
Analysis Lines 249.77 nm
Hollow cathode lamp Boron L2433-5NQ

Hollow cathode lamp Boron L2433-5NQ

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Boron

Specifications  
Lamp Diameter
38
Element symbol B
Element Name Boron
Analysis Lines (Maximum absorption wavelength) 249.68 nm
Analysis Lines 249.77 nm
Hollow cathode lamp Cadmium L2433-48NQ

Hollow cathode lamp Cadmium L2433-48NQ

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Cadmium

Specifications  
Lamp Diameter
38
Element symbol Cd
Element Name Cadmium
Analysis Lines (Maximum absorption wavelength) 228.8 nm
Analysis Lines - nm
Hollow cathode lamp Calcium L2433-20NU

Hollow cathode lamp Calcium L2433-20NU

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Calcium

Specifications  
Lamp Diameter
38
Element symbol Ca
Element Name Calcium
Analysis Lines (Maximum absorption wavelength) 422.67 nm
Analysis Lines - nm
Hollow cathode lamp Calcium Magnesium  L733-202NU

Hollow cathode lamp Calcium Magnesium L733-202NU

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Calcium Magnesium

Specifications  
Lamp Diameter
38
Element symbol Ca-Mg
Element Name Calcium Magnesium
Analysis Lines (Maximum absorption wavelength) - nm
Analysis Lines - nm

Hollow cathode lamp Calcium Magnesium Zinc L733-322NQ

Hollow cathode lamp Calcium Magnesium Zinc L733-322NQ

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Calcium Magnesium Zinc

Specifications  
Lamp Diameter
38
Element symbol Ca-Mg-Zn
Element Name Calcium Magnesium Zinc
Analysis Lines (Maximum absorption wavelength) - nm
Analysis Lines - nm
Hollow cathode lamp Chromium L2433-24NB

Hollow cathode lamp Chromium L2433-24NB

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Chromium

Specifications  
Lamp Diameter
38
Element symbol Cr
Element Name Chromium
Analysis Lines (Maximum absorption wavelength) 357.87 nm
Analysis Lines 425.44 nm
Hollow cathode lamp Cobalt L2433-27NU

Hollow cathode lamp Cobalt L2433-27NU

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Cobalt

Specifications  
Lamp Diameter
38
Element symbol Co
Element Name Cobalt
Analysis Lines (Maximum absorption wavelength) 240.73 nm
Analysis Lines 346.58 nm
Hollow cathode lamp Copper  L2433-29NB

Hollow cathode lamp Copper L2433-29NB

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Copper

Specifications  
Lamp Diameter
38
Element symbol Cu
Element Name Copper
Analysis Lines (Maximum absorption wavelength) 324.75 nm
Analysis Lines 327.4 nm
Hollow cathode lamp Dysprosium L233-66NB

Hollow cathode lamp Dysprosium L233-66NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Dysprosium

Specifications  
Lamp Diameter
38
Element symbol Dy
Element Name Dysprosium
Analysis Lines (Maximum absorption wavelength) 404.59 nm
Analysis Lines 421.17 nm
Hollow cathode lamp Erbium  L2433-68NB

Hollow cathode lamp Erbium L2433-68NB

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Erbium

Specifications  
Lamp Diameter
38
Element symbol Er
Element Name Erbium
Analysis Lines (Maximum absorption wavelength) 400.79 nm
Analysis Lines 415.11 nm
Hollow cathode lamp Erbium L233-68NB

Hollow cathode lamp Erbium L233-68NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Erbium

Specifications  
Lamp Diameter
38
Element symbol Er
Element Name Erbium
Analysis Lines (Maximum absorption wavelength) 400.79 nm
Analysis Lines 415.11 nm
Hollow cathode lamp Europium L233-63NB

Hollow cathode lamp Europium L233-63NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Europium

Specifications  
Lamp Diameter
38
Element symbol Eu
Element Name Europium
Analysis Lines (Maximum absorption wavelength) 459.4 nm
Analysis Lines 462.72 nm
Hollow cathode lamp Europium L2433-63NB

Hollow cathode lamp Europium L2433-63NB

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Europium

Specifications  
Lamp Diameter
38
Element symbol Eu
Element Name Europium
Analysis Lines (Maximum absorption wavelength) 459.4 nm
Analysis Lines 462.72 nm
Hollow cathode lamp Gadolinium L233-64NB

Hollow cathode lamp Gadolinium L233-64NB

For atomic absorption analysis, Metal-vapor discharge lamp, Element : Gadolinium

Specifications  
Lamp Diameter
38
Element symbol Gd
Element Name Gadolinium
Analysis Lines (Maximum absorption wavelength) 422.58 nm
Analysis Lines 407.58 nm
Hollow cathode lamp Gallium L2433-31NU

Hollow cathode lamp Gallium L2433-31NU

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Gallium

Specifications
 
Lamp Diameter
38
Element symbol Ga
Element Name Gallium
Analysis Lines (Maximum absorption wavelength) 294.36 nm
Analysis Lines 287.42 nm
Hollow cathode lamp Germanium L2433-32NU

Hollow cathode lamp Germanium L2433-32NU

For S-H background correction atomic absorption analysis, Metal-vapor discharge lamp, Element : Germanium

Specifications  
Lamp Diameter
38
Element symbol Ge
Element Name Germanium
Analysis Lines (Maximum absorption wavelength) 265.16 nm
Analysis Lines - nm
  • «
  • 1
  • 2
  • »

Lihat Juga

Gas Cylinder Cabinet
Gas Cylinder Cabinet
Polyethylene Acid Corrosive Cabinet
Polyethylene Acid Corrosive Cabinet
Series Ultrapure Water System
Series Ultrapure Water System
 Kjeldahl Digestion ststem SH420F
Kjeldahl Digestion ststem SH420F
Semi-Micro Analytical Balances
Semi-Micro Analytical Balances
Analitical Balance 120 gr
Analitical Balance 120 gr
Analytical Balances 220 Gr
Analytical Balances 220 Gr
FUME HOOD COMPLETE Ductless
FUME HOOD COMPLETE Ductless
Atomic Absorption Spectrophotometer
Atomic Absorption Spectrophotometer
Analytical Semimicro
Analytical Semimicro
Muffle Furnaces with Flap Door or Lift Door
Muffle Furnaces with Flap Door or Lift Door
Ashing Furnaces with Flap Door or Lift Door
Ashing Furnaces with Flap Door or Lift Door
Information
  • Beranda
  • Cara Beli
  • Tentang Kami
  • Kontak Kami
  • Peta Situs
  • Konfirmasi Pembayaran
  Pembayaran
  • BCA
  • transfer ke no rekening : atas nama 

  • Mandiri
  Customer Service
  •  081246390570
  •  081237955050
  •  082147530001
  Tentang Kami

© 2018 www.labkesprima.com

Top